SERIES 35 “ROVER” 12VDC PORTABLE LIFT P.O. Box 1058 1058 West Industrial Avenue Guthrie, OK 73044-1058 405-282-5200 FAX: 40
10 Figure 2 Label Placement - Standard Platform Series 35 Rover Item No. Qty Description Part No. 1 2 Caution – Familiarize Yourself
11 Note: Labels shown here are not actual size. Figure 3 Label 36401487 Figure 4 Label 36430050 Figure 5 Label 36401511 LABEL IDENTIFI
12 Figure 6 Label 36400661 Figure 7 Label 36402980 Figure 8 Label 36401586 LABEL IDENTIFICATION
13 * Varies depending on amp draw in battery LOAD CAPACITY The load capacity rating is stamped on a metal plate attached to the lift. This fig
14 WARNING ! Only authorized personnel should perform inspection or maintenance and service procedures. Unauthorized personnel attempting thes
15 Figure 9 Maintenance Locks LIFT BLOCKING INSTRUCTIONS
16 DANGER ! If for any reason you are unable to lower the lift completely onto the maintenance device(s), stop immediately and consult the fac
17 OIL The Rover is shipped with oil in the power unit. There is no need to fill it. STANDARD DC UNIT WARNING! Read and understand all of t
18 OPTIONAL 115/60 AC UNIT WARNING! Read and understand all of the instructions carefully before proceeding with the installation process.
19 OPTIONAL AIR POWER UNIT UNIT WARNING! Read and understand all of the instructions carefully before proceeding with the installation proce
2 Identification and Inspection 3 Responsibility of Users/Owners 4 Safety Signal Words 5 Safety Practices 6
20 PROCEDURE FOR A LIFT ORDERED WITH AN ACCORDION SKIRT 1. Position the platform in the raised position. Install the maintenance locks (see “
21 Figure 10 Skirt Installation INSTALLATION INSTRUCTIONS
22 1. Operate this lift only on a firm, flat & level surface. 2. Place the lift in loading position and lock the floor lock when not being
23 WARNING! Before installing lift, read & follow the recommended safety practices in the Safety Practices section. Failure to follow these
24 Oil Viscosity Recommendations Environment (Ambient Temperatures) Recommended Oil Indoor location, variable temperatures (30 - 100° F) 10W3
25 WARNING! Before installing lift, read & follow the recommended safety practices in the Safety Practices section. Failure to follow these
26 14. Check the piston head nut for tightness and torque to 600-650 ft. lbs on 3 ½” bore cylinders or 850-950 ft. lbs. on 4” bore cylinders. T
27 VELOCITY FUSE REPLACEMENT DANGER! Do not attempt to remove the velocity fuse until the lift is securely supported with the maintenance loc
28 VELOCITY FUSERESERVOIRCHECK VALVESUCTIONLINEFILTERP.F.MRELIEFVALVEDOWN SOL.VALVEDOWN FLOW CONTROLLIFT CYLINDERPUMP ASSEMBLY PROVIDES THEFUNCTION
29 WIRING AUTOQUIP "SUPER TORQUE' MOTORS Because Autoquip "Super-Torque" motors actually deliver substantially more horsepo
3 IDENTIFICATION When ordering parts or requesting information or service on this lift, PLEASE REFER TO THE MODEL AND SERIAL NUMBER. This inf
30 MDOWN SOLENOIDDOWNPUMP / MOTORASSEMBLY-+UPDC MOTOR Figure 12 Electric Schematic; 12VDC GENERAL MAINTENANCE
31 AIRREQUIREDFREE AIR)MOTORLUBRICATOR(BY OTHERS).REGULATORSUPPLYAIR OPERATEDRELIEF VALVE, AIR OPERATED DOWNTHE FUNCTION OF CHECK VALVE, (WHEN USED
32 (WHITE)(BLACK)(RED)(ORANGE)24V.L3L1L2L1L23/4 HORSEPOWERMOTOR:115 VOLT1 PHASE60 CYCLE(BY OTHERS)60 CYCLE115 VOLT1 PHASEO.L.T2T3T1L2L1L1L2DN. SOL.
33 Figure 15 Guarded Footswitch Assembly GENERAL MAINTENANCE
34 Figure 16 Limit Switch Wiring Diagram GENERAL MAINTENANCE
35 PART # DESCRIPTION MECHANICAL 20046320 Swivel Caster with 5” Dia. Wheel 20046314 Rigid Caster with 5” Dia. Wheel 20079430 Floor Lock (M
36 PART # DESCRIPTION POWER UNITS - AC 20001137 Tongue & Groove Coupling 32701290 Down Solenoid Coil, 24 VAC 35105130 Pump, 1.4 GPM
37 DANGER! To avoid personal injury, NEVER go under the lift platform until the load is removed and the scissors mechanism is securely blocked
38 PROBLEM POSSIBLE CAUSE AND SOLUTION Lift does not raise. The battery may not be charged. Charge battery. Check for a line or hose lea
39 PROBLEM POSSIBLE CAUSE AND SOLUTION Lift won’t lower. The solenoid coil may be incorrectly wired, burned out, not rated for the voltage, or
4 DEFLECTION It is the responsibility of the user/purchaser to advise the manufacturer where deflection may be critical to the application. INSP
40 PROBLEM POSSIBLE CAUSE AND SOLUTION Lift seems bouncy during operation. Battery connections may be loose. Check connections. Lower
41 The user is solely responsible for using this equipment in a safe manner and observing all of the safety guidelines provided in the Owner
5 SAFETY ALERTS (Required Reading!) The following SAFETY ALERTS are intended to create awareness of owners, operators, and maintenance personnel o
6 Read and understand this manual and all labels prior to operating or servicing the scissors lift. All labels are provided in accordance with ANSI
7 WARNING! NEVER stand, sit or ride on the lift! WARNING! All warning and information decals should be in place as outlined in the “Label
8 CAUTION! Never run the pump for more than a couple of seconds without pumping oil. This applies to low oil conditions, improper motor rotati
9 Figure 1 Label Placement - Oversized Platform Series 35 Rover Item No. Qty Description Part No. 1 2 Caution – Familiarize Yoursel